Eaton 9E 6000 VA 4800 W Tower UPS
Product Features Description
Engineered for mission-critical IT infrastructure, industrial automation, and enterprise networking hardware, the Eaton 9E UPS, 6000 VA, 4800 W, Input: Hardwired, Output: Hardwired, Tower provides double-conversion online power protection. It protects against power sags, surges, line noise, and extended blackouts.
-
Enterprise Online Double-Conversion Topology: The Eaton 9E UPS, 6000 VA, 4800 W, Input: Hardwired, Output: Hardwired, Tower unit delivers pure sine wave output by constantly monitoring incoming power and regulating both output voltage and frequency.
-
High Power Capacity for Heavy Workloads: Designed to protect critical servers and sensitive network loads, the Eaton 9E UPS, 6000 VA, 4800 W, Input: Hardwired, Output: Hardwired, Tower handles total continuous output loads up to 4800 Watts with a 0.8 power factor rating.
-
Hardwired Terminal Block Connections: Built for direct integration into electrical distribution panels, the Eaton 9E UPS, 6000 VA, 4800 W, Input: Hardwired, Output: Hardwired, Tower features secure AC input and AC output terminal blocks for high-amperage electrical wiring.
-
Intuitive Real-Time LCD Interface: Monitor operational status, battery levels, input/output voltages, and alarm configurations seamlessly on the Eaton 9E UPS, 6000 VA, 4800 W, Input: Hardwired, Output: Hardwired, Tower front panel menu.
-
Internal Automatic & Maintenance Bypass: Maintain service continuity without dropping connected loads during system maintenance or fault conditions using the Eaton 9E UPS, 6000 VA, 4800 W, Input: Hardwired, Output: Hardwired, Tower internal bypass mechanism.
-
Robust Floor-Standing Tower Form Factor: The Eaton 9E UPS, 6000 VA, 4800 W, Input: Hardwired, Output: Hardwired, Tower offers a footprint that integrates into server rooms, network closets, and medical equipment rooms.
-
Virtualization Integration & Smart Management: Enhance control across hypervisors using USB, RS232, or optional Network Management Cards installed in the Eaton 9E UPS, 6000 VA, 4800 W, Input: Hardwired, Output: Hardwired, Tower expansion slot.
Specifications
Eaton 9E 6000 VA 4800 W Tower UPS Pros & Benefits
-
Complete Isolation & Power Protection: Online double-conversion technology shields connected equipment from dirty power, voltage spikes, and frequency fluctuations.
-
High Load Capacity: 4800-Watt rating provides battery runtime and surge absorption for data racks, telecom switches, and broadcast gear.
-
Direct Electrical Wiring: Hardwired input and output terminals eliminate reliance on standard wall plugs, supporting installation into dedicated sub-panels.
-
Expandable Monitoring: Supports optional SNMP network interface cards for remote management, email alerts, and graceful multi-server shutdowns.
Eaton 9E 6000 VA 4800 W Tower UPS Price Matrix
Eaton 9E 6000 VA 4800 W Tower UPS Suitable Application Areas
-
Data Centers & Server Rooms: Powering multi-server racks, NAS storage systems, and core network switches.
-
Medical & Diagnostic Laboratories: Providing clean voltage regulation for diagnostic analyzers and imaging machinery.
-
Industrial Automation & SCADA Systems: Safeguarding PLCs and industrial process control panels against main grid sags and outages.
-
Telecommunications Hubs: Maintaining continuous power flow to remote PBX towers, fiber distribution nodes, and VOIP systems.
Installation Guide & User Support Manuals
-
Unpacking: Position the UPS packaging upright on a flat surface, open the crate, and use appropriate lifters to place the tower unit in a ventilated location with 500mm clearance front and back.
-
Upstream Electrical Prep: Verify that an upstream magneto-thermal circuit breaker (recommended 63A) is installed and switched OFF prior to wiring.
-
Hardwire Input/Output Connections: Remove the terminal block access cover on the rear panel. Connect protective earth (PE) first, followed by Neutral (N) and Live (L) conductors using minimum 6mm² copper cables.
-
Initial Power On: Re-attach terminal block covers. Turn on the upstream AC breaker, allow the internal self-test to execute, and press the front LCD power button for >2 seconds.
-
Software Configuration: Connect the USB or RS232 cable to your host server to configure shutdown sequences.
-
Download the full technical manual and wiring schematics: Eaton 9E UPS Installation Guide & User Support Manuals.
-
Browse power distribution equipment at Shop for more UPS deals at Potent.it.
Available Purchase Options
-
In-Store Purchase: Available in store at our Nairobi CBD fulfillment location for physical verification and order pickup.
-
Online Purchase & Countrywide Delivery: Order online directly at potent.it to arrange fast, fully insured delivery anywhere across Kenya.
FAQs
Q: Can I connect the Eaton 9E 6000 VA UPS to a standard wall socket?
A: No. Because this UPS has a high-amperage 4800W rating, both input and output lines require direct hardwiring by a qualified electrician to a dedicated circuit breaker panel.
Q: Does the Eaton 9E 6000 VA support runtime extension?
A: Yes, optional external battery modules (EBM) can be wired directly to the rear panel battery port to extend continuous operation during extended power outages.
Q: Does this UPS output pure sine wave power?
A: Yes. Utilizing online double-conversion architecture, it produces a clean pure sine wave output independent of grid frequency or voltage distortion.
What is in the Box?
-
1× Eaton 9E UPS 6000 VA / 4800 W Tower Unit (9E6KI)
-
1× Serial (RS232) Communication Cable
-
1× USB Interface Cable
-
1× Terminal Block Hardware Accessories Set
Verdict
The Eaton 9E UPS, 6000 VA, 4800 W, Input: Hardwired, Output: Hardwired, Tower provides online double-conversion backup power for high-density environments. Featuring hardwired input/output wiring, zero transfer time, and customizable network integration, it protects critical IT assets against power disruptions. Secure your power backup system today at Shop for more UPS deals at Potent.it.





There are no reviews yet.